šŸŽ‰ Up to 70% Off Selected ItemsShop Sale
HomeStore

Oakton (WD-35624-20) pH Tester 2 DBL-JUNCT; +0.1 pH; ATC

Product image 1

Oakton (WD-35624-20) pH Tester 2 DBL-JUNCT; +0.1 pH; ATC

The Oakton WD-35624-20 pH Tester 2 with double junction electrode delivers laboratory-grade accuracy of ±0.1 pH in a floating, waterproof design built for fieldwork and harsh applications. Replaceable electrode design with automatic temperature compensation and three-point calibration ensures long-term value and reliable measurement across -1.0 to 15.0 pH range.
SPECIFICATIONS

Core Performance Metrics

pH Range
-1.0 to 15.0
Full scale measurement
Accuracy
±0.1 pH
Laboratory grade precision
Resolution
0.1 pH
Clear readout increments
Calibration
3-Point
4.0, 7.0, 10.0 pH buffers
Electrode Type
Double Junction
Replaceable design
Waterproof Rating
IP67
Floats on water
TECHNICAL DETAILS

Full Specifications

Model Number Oakton WD-35624-20
Temperature Compensation Automatic (ATC), 0 to 50°C (32 to 122°F)
Microprocessor Features Auto buffer recognition, hold function, auto-off, error messages
Power Supply Three 1.5V batteries, 24-hour continuous runtime
Dimensions 6.5" Ɨ 1.5" diameter (16.5 cm Ɨ 3.8 cm)
Weight 4.5 oz (125 g) shipping weight
Construction IP67 waterproof and dustproof, buoyant housing
COMPATIBILITY & APPLICATIONS

Ideal Use Cases

The Oakton pH Tester 2 with double junction electrode is engineered for water treatment professionals, aquaculture operations, hydroponics systems, and field testing environments where electrode fouling is a concern. The double junction design with increased reference gel volume extends electrode life in harsh applications including high-TDS water, heavy metal solutions, and protein-rich samples. The replaceable electrode body allows you to maintain the same tester unit across multiple electrode lifecycles, reducing long-term equipment costs. Floating design prevents loss in tanks, ponds, or waterways. Push-button calibration and ATC make this suitable for technicians who need accurate readings across varying temperature conditions without manual compensation calculations.

šŸ’§ The double junction electrode design is critical for applications with sulfides, heavy metals, or Tris buffer solutions that would quickly poison a standard single-junction reference. Replace just the electrode when performance degrades rather than the entire tester unit.
The Oakton WD-35624-20 pH Tester 2 with double junction electrode delivers laboratory-grade accuracy of ±0.1 pH in a floating, waterproof design built for fieldwork and harsh applications. Replaceable electrode design with automatic temperature compensation and three-point calibration ensures long-term value and reliable measurement across -1.0 to 15.0 pH range.
SPECIFICATIONS

Core Performance Metrics

pH Range
-1.0 to 15.0
Full scale measurement
Accuracy
±0.1 pH
Laboratory grade precision
Resolution
0.1 pH
Clear readout increments
Calibration
3-Point
4.0, 7.0, 10.0 pH buffers
Electrode Type
Double Junction
Replaceable design
Waterproof Rating
IP67
Floats on water
TECHNICAL DETAILS

Full Specifications

Model Number Oakton WD-35624-20
Temperature Compensation Automatic (ATC), 0 to 50°C (32 to 122°F)
Microprocessor Features Auto buffer recognition, hold function, auto-off, error messages
Power Supply Three 1.5V batteries, 24-hour continuous runtime
Dimensions 6.5" Ɨ 1.5" diameter (16.5 cm Ɨ 3.8 cm)
Weight 4.5 oz (125 g) shipping weight
Construction IP67 waterproof and dustproof, buoyant housing
COMPATIBILITY & APPLICATIONS

Ideal Use Cases

The Oakton pH Tester 2 with double junction electrode is engineered for water treatment professionals, aquaculture operations, hydroponics systems, and field testing environments where electrode fouling is a concern. The double junction design with increased reference gel volume extends electrode life in harsh applications including high-TDS water, heavy metal solutions, and protein-rich samples. The replaceable electrode body allows you to maintain the same tester unit across multiple electrode lifecycles, reducing long-term equipment costs. Floating design prevents loss in tanks, ponds, or waterways. Push-button calibration and ATC make this suitable for technicians who need accurate readings across varying temperature conditions without manual compensation calculations.

šŸ’§ The double junction electrode design is critical for applications with sulfides, heavy metals, or Tris buffer solutions that would quickly poison a standard single-junction reference. Replace just the electrode when performance degrades rather than the entire tester unit.
$72.29

Original: $206.55

-65%
Oakton (WD-35624-20) pH Tester 2 DBL-JUNCT; +0.1 pH; ATC—

$206.55

$72.29

Description

The Oakton WD-35624-20 pH Tester 2 with double junction electrode delivers laboratory-grade accuracy of ±0.1 pH in a floating, waterproof design built for fieldwork and harsh applications. Replaceable electrode design with automatic temperature compensation and three-point calibration ensures long-term value and reliable measurement across -1.0 to 15.0 pH range.
SPECIFICATIONS

Core Performance Metrics

pH Range
-1.0 to 15.0
Full scale measurement
Accuracy
±0.1 pH
Laboratory grade precision
Resolution
0.1 pH
Clear readout increments
Calibration
3-Point
4.0, 7.0, 10.0 pH buffers
Electrode Type
Double Junction
Replaceable design
Waterproof Rating
IP67
Floats on water
TECHNICAL DETAILS

Full Specifications

Model Number Oakton WD-35624-20
Temperature Compensation Automatic (ATC), 0 to 50°C (32 to 122°F)
Microprocessor Features Auto buffer recognition, hold function, auto-off, error messages
Power Supply Three 1.5V batteries, 24-hour continuous runtime
Dimensions 6.5" Ɨ 1.5" diameter (16.5 cm Ɨ 3.8 cm)
Weight 4.5 oz (125 g) shipping weight
Construction IP67 waterproof and dustproof, buoyant housing
COMPATIBILITY & APPLICATIONS

Ideal Use Cases

The Oakton pH Tester 2 with double junction electrode is engineered for water treatment professionals, aquaculture operations, hydroponics systems, and field testing environments where electrode fouling is a concern. The double junction design with increased reference gel volume extends electrode life in harsh applications including high-TDS water, heavy metal solutions, and protein-rich samples. The replaceable electrode body allows you to maintain the same tester unit across multiple electrode lifecycles, reducing long-term equipment costs. Floating design prevents loss in tanks, ponds, or waterways. Push-button calibration and ATC make this suitable for technicians who need accurate readings across varying temperature conditions without manual compensation calculations.

šŸ’§ The double junction electrode design is critical for applications with sulfides, heavy metals, or Tris buffer solutions that would quickly poison a standard single-junction reference. Replace just the electrode when performance degrades rather than the entire tester unit.